Personal / public technical prototype
5 V / 200 mA
SMPS.
An offline flyback prototype documented from transformer winding and component selection through waveform capture and bench validation.
01 / Objective
Turn a power stage
into evidence.
The project follows an offline flyback prototype through transformer and component decisions, schematics or BOM material, waveform capture and bench validation notes.
This is a personal public prototype. It is not presented as a certified supply, production design, commercial deployment or guaranteed output result.
02 / Scope
Magnetics,
switching, tests.
Technical scope
The repository provides a traceable record of transformer work, component selection, schematic/BOM material, captured switching waveforms and bench observations.
Offline flyback prototype.
Bench measurements and waveform review.






03 / Evidence
Measured under
stated conditions.
This gallery is curated from existing project photographs supplied with the public SMPS repository. Captions identify the documented subject and source file; no values or validation claims are inferred beyond what the photographs show.
Documented bench result: approximately 4.94 V across a 22 Ω load with approximately 200 mA reported bench current. The 1 A designation is the intended output target; 1 A bench operation was not demonstrated by this record.
Start a technical discussion
Bring the
prototype.
Describe the converter, current stage, measured behavior and the design decision you need to make. Secure file exchange can follow the initial discussion.
Start a Technical Discussion →Or write directly: Email us