Personal / public technical prototype

5 V / 200 mA
SMPS.

An offline flyback prototype documented from transformer winding and component selection through waveform capture and bench validation.

FLYBACKTNY285MAGNETICSWAVEFORMSVALIDATION

Turn a power stage
into evidence.

The project follows an offline flyback prototype through transformer and component decisions, schematics or BOM material, waveform capture and bench validation notes.

This is a personal public prototype. It is not presented as a certified supply, production design, commercial deployment or guaranteed output result.

Magnetics,
switching, tests.

Technical scope

The repository provides a traceable record of transformer work, component selection, schematic/BOM material, captured switching waveforms and bench observations.

Topology

Offline flyback prototype.

Validation

Bench measurements and waveform review.

Measured under
stated conditions.

This gallery is curated from existing project photographs supplied with the public SMPS repository. Captions identify the documented subject and source file; no values or validation claims are inferred beyond what the photographs show.

Documented bench result: approximately 4.94 V across a 22 Ω load with approximately 200 mA reported bench current. The 1 A designation is the intended output target; 1 A bench operation was not demonstrated by this record.

Start a technical discussion

Bring the
prototype.

Describe the converter, current stage, measured behavior and the design decision you need to make. Secure file exchange can follow the initial discussion.

Start a Technical Discussion

Or write directly: Email us